The pressure oil in the lower chamber of the variable housing enters the upper chamber of the variable housing through the oil passage hole in the variable piston. As the area of the upper chamber is larger than the lower chamber, the hydraulic pressure pushes the piston downward and drives the pin shaft
Rotate the variable head around the center of the steel ball,
Changing the tilt angle of the variable head increases the flow rate of the plunger pump. On the contrary, when the pull rod moves upward, the tilt angle of the variable head changes in the opposite direction, and the pump flow also changes
It changes accordingly. When the tilt angle becomes zero,
The variable head changes in the direction of negative deflection angle, the liquid flow changes direction, and the inlet and outlet of the pump change.