EFBG EFBG-03 EFBG-03-125- C-20T233-L-H high flow series proportional electro-hydraulic flow control and relief valve
Instructions Drain Back Pressure Check that the drain back pressure does not exceed 2 Kgf/cm2 When Relief Valve Passing Flow Rate is Low in Pressure Control State To avoid preselected pressure instability, use a passing flow rate of 10L/min. or higher for nominal sizes 03 and 06 or 15 L/min. Further, check that the tank-line back pressure does not exceed 5 Kgf/cm2 Safety Valve Pressure Setting The safety valve is preset to a pressure that is 2 Kgf/cm2 higher than the maximum adjustment pressure. Therefore, adjust this pressure setting as needed to suit the pressure used. To lower the pressure setting, turn the safety valve pressure adjustment screw anti-clockwise. After adjustment, be sure to tighten the lock nut.





![]()

![]()