Influence of case pressure on beginning of control An increase in case pressure affects the beginning of control when using the following control options: ▶ HD, EP, HA, HA.T: Increase ▶ DA: Decrease With the following settings, an increase in case pressure will have no effect on the beginning of control: HA.R and HA.U, EP, HA The factory setting of the beginning of control is made at pabs = 15 psi (1 bar) case pressure
Permissible pressure loading The service life of the shaft seal is influenced by the rotational speed of the axial piston unit and the leakage pressure in the housing (case pressure). Momentary (t < 0.1 s) pressure peaks of up to 145 psi (10 bar) are allowed. Case pressures of a continuous 30 psi (2 bar) maximum are permitted to be able to utilize the entire speed range. Higher case pressures are permissible at lower rotational speeds (see diagram). The service life of the shaft seal decreases with increasing frequency of pressure peaks and increasing mean differential pressure. The case pressure must be equal to or higher than the ambient pressure
The FKM shaft seal ring may be used for leakage temperatures from -13 °F to +240 °F (-25 °C to +115 °C). For application cases below -13 °F (-25 °C), an NBR shaft seal is required (permissible temperature range: -40 °F to +195 °F (-40 °C to +90 °C).



![]()

![]()

![]()