Principle of recoil solenoid valve: its principle is that the direct action and pilot phase are different. When the solenoid valve is energized, the auxiliary valve is turned over first. The pressure of the lower chamber of the main valve is greater than the pressure of the upper chamber, and the valve is opened by the simultaneous action of differential pressure and solenoid valve; In case of power failure, the auxiliary valve shall push the closing part with spring force or medium pressure, and move it downward to close the valve. Features: It can also work under zero differential pressure or high pressure, but the power and volume are large, so the device is required. 3、 Principle of pilot operated solenoid valve: when the pilot valve is energized, the solenoid force drives the pilot valve to open the pilot valve, the pressure in the upper chamber of the main valve drops rapidly, forming a pressure difference between the upper chamber and the lower chamber of the main valve, and relying on the medium pressure to promote the closure of the main valve to move up, the valve opens; When the power is cut off, the pilot valve is closed by the spring force, and the inlet medium pressure quickly enters the upper chamber of the main valve through the pilot hole to form a differential pressure, thus closing the main valve. Features: small size, low power, but the medium pressure difference is limited, and the pressure difference condition is necessary. The two position three-way solenoid valve is usually used together with the single acting pneumatic actuator. The two positions are controllable: open close. The three-way valve has three channels for ventilation. Under normal conditions, one channel is connected with the air source, the other two channels are connected with the air inlet of the actuator, and the other one is connected with the exhaust port of the actuator. The detailed working principle can refer to the working principle diagram of the single acting pneumatic actuator. The two position five way solenoid valve is usually used together with the double acting pneumatic actuator. The two position five way solenoid valve is controllable: open close. The five way solenoid valve has five channels for ventilation, one of which is connected with the air source, two of which are connected with the air inlet and outlet of the external air chamber of the double acting cylinder, and two of which are connected with the air inlet and outlet of the partial air chamber. The detailed working principle can be referred to the working principle of the double acting pneumatic actuator in terms of the air circuit (or liquid circuit), The two position three-way solenoid valve has one air inlet (connected to the air supply), one air outlet (to provide the air supply for the target equipment) and one air outlet



![]()

![]()

![]()