When the motor shaft and pump shaft are assembled using couplings, the parallelism error should be within 0.05mm and the angle error should be within 1 degree. It is generally recommended to use a dedicated motor for direct oil pumps.
Precautions for using vane pump VVPE-F30D-30D-10:
The external oil drain port of the variable displacement pump must have its oil drain pipe directly connected to the oil tank and cannot be returned through other oil pipes. The oil drain pipe must be under the oil level.
The pump oil suction port should not be 1 meter above the oil level.
The working temperature of the hydraulic oil connection should be maintained within the range of 15 to 60 degrees. If it is below 15 degrees, please use a heater. If it is above 60 degrees, please use a cooler.
Hydraulic oil: below 70bar, use hydraulic oil with a viscosity of 30-50cSt (ISO VG32) at 40 ℃.
Above 70 bar, use hydraulic oil with a viscosity of 50-70 cSt (ISO VG32) at 40 ℃.
Pressure of drain pipe: The drain pipe must be directly connected to the oil level of the oil tank, and the back pressure generated by the configuration should be maintained below 0.3 bar.
Operating oil temperature: The temperature for continuous operation is 15-16 ℃.
Shaft center fit: The shaft center error between the pump shaft and the motor shaft is 0.05mm, and the angle error is 1 degree.
Oil suction pressure: The pressure at the oil suction port is - 0.3 bar to 0.3 bar.
Displacement adjustment: When adjusting the displacement, first loosen the adjusting nut, then rotate the adjusting screw. Turn right to reduce the flow, while turn left to increase it. After adjustment, tighten the screw.
Pressure adjustment: Turn the pressure adjustment screw right to reduce the output pressure, and turn left to increase it.
*Large peak value: * The large peak value shall not exceed 140 bar. A3 type * Large peak value shall not exceed 140 bar.
New machine operation: When the new machine starts to operate, the motor can be repeatedly started without pressure to remove air from the pump and oil suction pipe. To ensure that the air in the system is removed, it can be continuously operated for 10 minutes without load