Eaton 70122 70422 70423 70523 series 70422-RFH 080211R121002 Pressure Piston Pumps 70422-RFH 080211R121002 Installation Requirements • Install piston pumps in such a position that the case drain assures an oil level at or above unit center line. • Oil level must be at center line or above before starting piston pump. • Provide a case drain line of adequate size to limit the case pressure to 2 bar [25 PSI] maximum. • Filtration is recommended. • The combined torque required to turn two or more pumps must not exceed the torque rating of the input drive shaft of the front piston pump |




![]()

![]()

![]()