Axis fit: The eccentricity error between the pump shaft and the motor is 0.05mm, and the angle error is 1 °
Oil suction pressure: The pressure at the oil suction port is -0.03MPa~0.03MPa
Displacement adjustment: When adjusting the displacement, first loosen the adjusting nut, then rotate the adjusting bolt, turn right to reduce the flow, and turn left to increase. After the adjustment is completed, please tighten the nut.
Pressure adjustment: Turn left (counterclockwise) to adjust the pressure bolt to reduce the output pressure, and turn right (clockwise) to increase it. After adjustment, please tighten the nut
New machine operation: When the new machine starts running, the motor should be repeatedly started without pressure to exhaust the air in the pump and oil suction pipe. To ensure that the air in the system is discharged, it can be continuously operated for 10 minutes without load