Nachi high pressure IPH IPH-44B IPH-45B IPH-46B IPH-56B series IPH-46B-32-100-EE-1 hydraulic gear pumps.
IPH Series IP Pump
IPH Series IP Pump
Specifications
startup is 40°F or less, perform a
warm-up operation at low pressure until
the oil temperature reaches 40°F. Use
the pump in an area where the tempera- ture is within the range of 32 to 140°F.
Suction pressure 3.6 psi, and
the suction port flow rate should be to
greater than 5 ft/sec.
Avoid pulley, gear, and other drive
systems that impart a radial or thrust load
on the end of the pump shaft.
Mount the hydraulic pump so its pump
shaft is oriented horizontally. Provide a
suction strainer with a filtering grade of
about 100μm (150 mesh). For the return
line to the tank, use a 10μm line filter.
Manage hydraulic operating fluid so
contamination is maintained at class
NAS10 or lower. Take care to avoid
contamination with water and other
foreign matter, and watch out for
discoloration. Whitish fluid indicates that
air has contaminated the fluid, and
brownish fluid indicates the fluid is dirty






![]()

![]()

![]()