5.Working pressure is continuous operating pressure when the same pressure exists on the head side and shaft side. 6.Individual pump perform performance on the head side and shaft side is the same as that of the single pumps. Required power is the sum of the power required by each of the two pumps. 7.The "Required Power at 1200min-1, 3045 psi (hp)" column in the above table are based on combinations that provide the maximum capacity for each model number, when pressure at both the head side and shaft side is 3045 psi. Examples combinations that provide "the maximum capacity for each model number" are IPH-22B-8-8-11 for IPH-22b, and IPH-46B-32- 125-11 for IPH-46B. • Handling Handling is in accordance with procedures for the IPH pump. See page C-1 for more information.



![]()

![]()

![]()