According to the working principle of YUKEN plunger pump, when the motor drives the transmission shaft to rotate, the pump cylinder and plunger rotate together, and the plunger head always keeps in contact with the swashplate. Since the swashplate is at an angle with the cylinder block, the plunger will reciprocate in the pump cylinder when the cylinder block rotates. Take the next plunger in Figure l-40 as an example. It turns from 0 ° to 180 °, that is, to the position of the upper plunger. The volume of the plunger cylinder gradually increases, so the liquid is sucked into the oil cylinder through the oil suction port a of the oil distribution plate; When the plunger is turned from 180 ° to 360 °, the volume of the plunger cylinder decreases gradually, so the liquid in the cylinder is discharged through the outlet of the oil distribution plate. As long as the drive shaft rotates continuously, the pump will work continuously.


![]()

![]()

![]()