Pvs Series Pvs-2b-35n3-12 Pvs-2b-35n1-12 Pvs-2b-35n2-12 PVS-2B-35N0-12 Pzs-3b-70n4-10
Use good-quality hydraulic operating fluid, and use within a kinematic viscosity range of 20 to 200 centistokes during operation. Use an R&O type and antiwear hydraulic fluid of ISO-VG32 to 68. The optimum kinematic viscosity during
operation is 20 to 50 centistokes. The operating temperature range is 40 to 190º F. When the oil temperature at startup is 40º F or less, warm up the hydraulic pump by low-pressure, low-operation speed operation until the oil temperature reaches 40°F. Provide a suction strainer with a filtering grade of about 100μm (150 mesh). Be sure to provide a return line filter of grade 10μm or less on the return line to the tank. (When the hydraulic pump is used at a high pressure of 2000 psi or more, we recommend providing a filter of 10μm or less. Manage the hydraulic operating fluid so that contamination is maintained at class NAS10 or lower. Use hydraulic operating fluid within an operating ambient temperature of 32 to 140º F.




![]()

![]()

![]()